LLPD d45z up to 52 kV (DLS) - order on Streamer
... 5 <280 95/95 2.8 65 20 (8/50µs) 10 0 1 visual verification/ year * According to IEC 60038 ... )***, C 2.8 High current impulse (4/10 μs), kA 65 Maximum quenching lightning current, kA 20 ... on the line, % 0 Average expected lifespan, years 30 UV resistance****, h 1000 Weight, kg 7 ...
LLPD d10z up to 12 kV (DLS) - order on Streamer
... Back Flashover No maintenance is required 12 5 <115 28/38 2.8 65 20 (8/50µs) 10 0 1 visual ... High current impulse (4/10 μs), kA 65 Maximum quenching lightning current, kA 20 (8/50µs ...
LLPD d24z up to 24 kV (DLS) - order on Streamer
... Back Flashover No maintenance is required 24 5 <150 40/50 2.8 65 20 (8/50µs) 10 0 1 visual ... High current impulse (4/10 μs), kA 65 Maximum quenching lightning current, kA 20 (8/50µs ...
https://streamer-electric.com/upload/tmp_download/admin/RENEWABLE-E...
... impulse (4/10 µs), kA 65 65 65 65 Maximum quenching lightning current, kA 20 (8/50µs) 3 (1/50µs) 20 (8 ... voltage, kV <200 <280 <440 Power frequency withstand voltage, kV (wet/dry) 65/80 95/95 140/140 Lightning ... impulse (4/10 µs), kA 65 65 65 65 Maximum quenching lightning current, kA 20 (8/50µs) 3 (1/50µs) 20 (8 ... voltage, kV <200 <280 <440 Power frequency withstand voltage, kV (wet/dry) 65/80 95/95 140/140 Lightning ...
LLPD dM35z up to 40,5 kV (DLS) - order on Streamer
... 65/80 2.8 65 20 (8/50 µs) 10 0 1 visual verification/ year * According to IEC 60038, ** According to ... voltage (180 mm air gap), kV <200 Power frequency withstand voltage**, kV (wet/dry) 65/80 Lightning ... parameters Lightning discharge capability (200 μs)***, C 2.8 High current impulse (4/10 μs), kA 65 ...
LLPD d69z up to 72,5 kV (DLS) - order on Streamer
... 2.8 65 20 (8/50µs) 10 0 1 visual verification/ year * According to IEC 60038, ** According to IEC ... parameters Lightning discharge capability (200 μs)***, C 2.8 High current impulse (4/10 μs), kA 65 ...
LLPD dC20z up to 24 kV (DLS) - order on Streamer
... Induced Overvoltage Protects from Back Flashover No maintenance is required 24 5 <185 40/50 2.8 65 20 (8 ... High current impulse (4/10 μs), kA 65 Maximum quenching lightning current, kA 20 (8/50µs ...
FAQ
... bolted connections temperature and terminals temperature rise shouldn’t exceed 50- 65 degrees compared to ... allow maintenance personnel to be up to date regarding equipment conditions 24/ 7. Moreover, the ... bolted connections temperature and terminals temperature rise shouldn’t exceed 50- 65 degrees compared to ... equipment conditions 24/ 7. Moreover, the scheduled inspection date and time can be unlucky, e.g., a period ...
LLPD i20z up to 24 kV (IOV) - order on Streamer
... line parameters 24 1,5 <110 30/40 2.4 65 3 (1/50µs) 10 0 1 visual verification/ year * According to ... capability (200 μs)***, C 2.4 High current impulse (4/10 μs), kA 65 Maximum quenching lightning ...
Pathfinder 360 Alpha Range - order on Streamer
... Fault Indication P360A (D, S, or F &FD) via LED P360A COM GSM via LED, SMS service P360A COM GPRS via ... indicator P360A COM GSM FO.P3.PL3G.00.WW Fault indicator P360A COM GPRS FO.P3.PL3P.00.WW ✕ Streamer Inc ...