70 Ergebnisse für "maintenance"

REECH AG – Gestalten Sie mit uns die erneuerbare Energiezukunft

... alpine systems, technology management, product development, planning, construction and maintenance ... , construction and maintenance covering all aspects of renewable energy and photovoltaics. Shape the future of ... & maintenance Photovoltaics On buildings On infrastructure Ground-mounted photovoltaics Photovoltaic energy ...

LLPD d10z up to 12 kV (DLS) - order on Streamer

...  Back Flashover No maintenance  is required 12 5 <115 28/38 2.8 65 20 (8/50µs) 10 0 1 visual ... Protects from  Induced Overvoltage Protects from Back Flashover No maintenance  is required Parameters of ... line, % 0 Average expected lifespan, years 30  UV resistance****, h 1000  Weight, kg 1.1   Maintenance ...

LLPD d24z up to 24 kV (DLS) - order on Streamer

...  Back Flashover No maintenance is required 24 5 <150 40/50 2.8 65 20  (8/50µs) 10 0 1 visual ... Protects from Induced Overvoltage Protects from Back Flashover No maintenance is required Parameters of ...   Maintenance 1 visual verification/year * According to IEC 60038, ** According to IEC 60071-1, *** According to ...

First TRANSEC installation Nicaragua - articles by Streamer Electric

... development and wind power plant maintenance. TRANSEC was introduced for drying transformers 230 kV, 60 MVA ... maintenance, which required its shutdown. Therefore, during the first hours of TRANSEC operation, sensor ... wind power plant maintenance. TRANSEC was introduced for drying transformers 230 kV, 60 MVA. One of the ... monitoring of indicators. This time, TRANSEC has been installed during the transformer maintenance, which ...

Surge and Lightning Monitoring

... detection. Outdoor and durable device: IP67, glass window, stainless steel, aluminium. No maintenance: self ... , glass window, stainless steel, aluminium. No maintenance: self-powered device, no battery. Easy counter ...

Products

... turn sends ALARM signal to maintenance personnel through Modbus, dry contact relay, or via SMS in case ... and industrial companies to a new level of safety and maintenance efficiency. 4. Monitoring of ... gas is detected by FPA, which in turn sends ALARM signal to maintenance personnel through Modbus, dry ... affordable price that takes utility and industrial companies to a new level of safety and maintenance ...

IT Traineeship | Gabera Foundation

... #, Python, Web, App, SPS, Data Mining, Robotics PLC Technician training (installation and maintenance ... , Robotics PLC Technician training (installation and maintenance)   (Track 2) PLC, electrical engineering ...

Pathfinder MK Range - order on Streamer

... the line's operation or maintenance team when a fault appears on the line. The Pathfinder MK helps to ... portable fault indicators. They are intended to be used by the line's operation or maintenance team when a ...

LLPD d45z up to 52 kV (DLS) - order on Streamer

... . Specifications  Protects from Direct Lightning Strike Protects from Back Flashover No maintenance is required 52 ... No maintenance is required Parameters of product Electrical line parameters Highest voltage for ... resistance****, h 1000  Weight, kg 7   Maintenance 1 visual verification/  year * According to IEC 60038 ...

LLPD d69z up to 72,5 kV (DLS) - order on Streamer

... Flashover No maintenance is required 72.5 5 50% flashover voltage (75+75+115 mm air gap), kV <400 140/140 ... Flashover No maintenance is required Parameters of product Electrical line parameters Highest voltage for ... lifespan, years 30  UV resistance****, h 1000  Weight, kg 9.3   Maintenance 1 visual verification/  year ...

Mehr Ergebnisse