LLPD d10z up to 12 kV (DLS) - order on Streamer
... Back Flashover No maintenance is required 12 5 <115 28/38 2.8 65 20 (8/50µs) 10 0 1 visual ... Protection against DLS, BFO Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per ... )***, C 2.8 High current impulse (4/10 μs), kA 65 Maximum quenching lightning current, kA 20 (8 ... current, kA 5.0 Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per pole Choose file ...
LLPD d24z up to 24 kV (DLS) - order on Streamer
... Back Flashover No maintenance is required 24 5 <150 40/50 2.8 65 20 (8/50µs) 10 0 1 visual ... Protection against DLS, BFO Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per ... )***, C 2.8 High current impulse (4/10 μs), kA 65 Maximum quenching lightning current, kA 20 ... current, kA 5.0 Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per pole Choose file ...
DocuWare | #1 Dokumentenmanagement (DMS) für KMU
... System (DMS) für smarte KMU. Deine digitale Zukunft beginnt jetzt. bewerten DocuWare als # 1 bei der ... DocuWare | # 1 Dokumentenmanagement (DMS) für KMU ... DocuWare | # 1 Dokumentenmanagement (DMS) für KMU Software DMS & Workflow DocuWare DMS & Büro ... DocuWare | # 1 Dokumentenmanagement (DMS) für KMU ...
LLPD dM35z up to 40,5 kV (DLS) - order on Streamer
... 65/80 2.8 65 20 (8/50 µs) 10 0 1 visual verification/ year * According to IEC 60038, ** According to ... Protection against DLS, BFO Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per ... voltage (180 mm air gap), kV <200 Power frequency withstand voltage**, kV (wet/dry) 65/80 Lightning ... parameters Lightning discharge capability (200 μs)***, C 2.8 High current impulse (4/10 μs), kA 65 ...
LLPD d45z up to 52 kV (DLS) - order on Streamer
... 5 <280 95/95 2.8 65 20 (8/50µs) 10 0 1 visual verification/ year * According to IEC 60038 ... Protection against DLS, BFO Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per ... parameters Lightning discharge capability (200 μs)***, C 2.8 High current impulse (4/10 μs), kA 65 ... current, kA 5.0 Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per pole Choose file ...
LLPD d69z up to 72,5 kV (DLS) - order on Streamer
... 2.8 65 20 (8/50µs) 10 0 1 visual verification/ year * According to IEC 60038, ** According to IEC ... Protection against DLS, BFO Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per ... μs), kA 65 Maximum quenching lightning current, kA 20 (8/50µs) Minimum withstand amount ... current, kA 5.0 Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per pole Choose file ...
LLPD dC20z up to 24 kV (DLS) - order on Streamer
... Induced Overvoltage Protects from Back Flashover No maintenance is required 24 5 <185 40/50 2.8 65 20 (8 ... Protection against DLS, BFO Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per ... High current impulse (4/10 μs), kA 65 Maximum quenching lightning current, kA 20 (8/50µs ... current, kA 5.0 Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per pole Choose file ...
LLPD i20z up to 24 kV (IOV) - order on Streamer
... line parameters 24 1,5 <110 30/40 2.4 65 3 ( 1/50µs) 10 0 1 visual verification/ year * According to ... Protection against: IOV Lightning discharge capability, C 2.4 Installation 1 piece per pole Choose ... current impulse (4/10 μs), kA 65 Maximum quenching lightning current, kA 3 ( 1/50µs) Minimum ... , kA 1.5 Lightning discharge capability, C 2.4 Installation 1 piece per pole Choose file ...
https://streamer-electric.com/upload/tmp_download/admin/RENEWABLE-E...
... impulse (4/10 µs), kA 65 65 65 65 Maximum quenching lightning current, kA 20 (8/50µs) 3 ( 1/50µs) 20 (8 ... voltage, kV <200 <280 <440 Power frequency withstand voltage, kV (wet/dry) 65/80 95/95 140/140 Lightning ... impulse (4/10 µs), kA 65 65 65 65 Maximum quenching lightning current, kA 20 (8/50µs) 3 ( 1/50µs) 20 (8 ... voltage, kV <200 <280 <440 Power frequency withstand voltage, kV (wet/dry) 65/80 95/95 140/140 Lightning ...
FAQ
... and terminals temperature rise shouldn’t exceed 50- 65 degrees compared to ambient air temperature in ... connection again. A loose connection can appear because of the following reasons: 1. Improper tightening ... 50- 65 degrees compared to ambient air temperature in the enclosure, which means 90-105 degrees of ... following reasons: 1. Improper tightening during assembly 2. Vibration over time 3. Large number of ...