DocuWare | #1 Dokumentenmanagement (DMS) für KMU
... System (DMS) für smarte KMU. Deine digitale Zukunft beginnt jetzt. bewerten DocuWare als # 1 bei der ... der Projektzusage bis zum GoLive zwischen 1.5 und 3 Monaten. Dank unseren Vorlagen, die auf Schweizer ... Automatische Updates CHF 1829 / Mt. Cloud 40 15 Benutzerlizenzen 100GB Speicherplatz 3-faches Backup ... DocuWare | # 1 Dokumentenmanagement (DMS) für KMU ... DocuWare | # 1 Dokumentenmanagement (DMS) für KMU ...
224 Schulzimmer, 1 Studie | Wuerfeli
... 224 Schulzimmer, 1 Studie | Wuerfeli ... https://wuerfeli.ch/224-schulzimmer- 1-studie/ ... 224 Schulzimmer, 1 Studie | Wuerfeli ...
LLPD d24z up to 24 kV (DLS) - order on Streamer
... Protection against DLS, BFO Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per ... Back Flashover No maintenance is required 24 5 <150 40/50 2.8 65 20 (8/50µs) 10 0 1 visual ... capability, C 2.8 Installation 1, 2 or 3 pcs per pole Choose file LLPD_CATA_ENG_2024 LP_OM_LLPD_d24z_2312_EN ... **, kV (wet/dry) 40/50 Lightning parameters Lightning discharge capability (200 μs)***, C 2.8 ...
https://streamer-electric.com/upload/tmp_download/admin/RENEWABLE-E...
... -ELECTRIC.COM22 8 12 13 9 9 7 6 5 11 11 1010 24 22 21 19 3 1 23 4 17 18 20 16 15 14 2 STREAMER ELECTRIC AG 23 ... impulse ( 4/10 µs), kA 65 65 65 65 Maximum quenching lightning current, kA 20 (8/50µs) 3 ( 1/50µs) 20 (8 ... -ELECTRIC.COM22 8 12 13 9 9 7 6 5 11 11 1010 24 22 21 19 3 1 23 4 17 18 20 16 15 14 2 STREAMER ELECTRIC AG 23 ... impulse ( 4/10 µs), kA 65 65 65 65 Maximum quenching lightning current, kA 20 (8/50µs) 3 ( 1/50µs) 20 (8 ...
LLPD dC20z up to 24 kV (DLS) - order on Streamer
... Protection against DLS, BFO Lightning discharge capability, C 2.8 Installation 1, 2 or 3 pcs per ... Induced Overvoltage Protects from Back Flashover No maintenance is required 24 5 <185 40/50 2.8 65 20 (8 ... capability, C 2.8 Installation 1, 2 or 3 pcs per pole Choose file LLPD_CATA_ENG_2024 LP_OM ... **, kV (wet/dry) 40/50 Lightning parameters Lightning discharge capability (200 μs)***, C 2.8 ...
LLPD i20z up to 24 kV (IOV) - order on Streamer
... line parameters 24 1,5 <110 30/ 40 2.4 65 3 ( 1/50µs) 10 0 1 visual verification/ year * According to ... Protection against: IOV Lightning discharge capability, C 2.4 Installation 1 piece per pole Choose ... current, kA 3 ( 1/50µs) Minimum withstand amount of operations 10 General Parameters Additional ... 2.4 Installation 1 piece per pole Choose file LLPD_CATA_ENG_2024 LP_OM_LLPD_i20z_2401_EN ...
Pathfinder MK Range - order on Streamer
... Min. fault current 4 A Fault indication Via red flag & SMS Installation 1 product per pole Choose ... electromagnetic fields in a single or 3-phases medium voltage network. Sensing is triggered when it detects fault ... current 4 A Fault indication Via red flag & SMS Installation 1 product per pole Choose file Streamer Fault ... balance electromagnetic fields in a single or 3-phases medium voltage network. Sensing is triggered when ...
FPA24(4S) OM firmware 1.2 Apr'22 edited
... LED-indicator ’’up’’, ‘‘down’’ bu�ons Main body Corded sensor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ... addresses sequen�ally, star�ng with 1, i.e. 1, 2, 3, 4,... FPA 24(4S) Opera�on Manual (Firmware version 1.2 ... -indicator ’’up’’, ‘‘down’’ buons Main body Corded sensor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 2 13 ... convenience it is beer to set addresses sequenally, starng with 1, i.e. 1, 2, 3, 4,... FPA 24(4S) Operaon ...
SC250 Surge Counter - order on Streamer
... ; outdoor Current transformers device The 3 current transformers SC250 is in all point similar to the 1 ... maintenance : self powered device, no battery Easy cable installation : up to 3 split cores current ... ; outdoor Current transformers device The 3 current transformers SC250 is in all point similar to the 1 ... , no battery Easy cable installation : up to 3 split cores current transformers, 5 to 25mm cable ...
FPA24(4S) OM
... ’’, ‘‘down’’ buttons Main body Corded sensor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 2 13 latch A B to ... addresses sequentially, starting with 1, i.e. 1, 2, 3, 4,... FPA 24(4S) Operation Manual 4 5.1 To set up ... ’’, ‘‘down’’ buttons Main body Corded sensor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 2 13 latch A B to ... addresses sequentially, starting with 1, i.e. 1, 2, 3, 4,... FPA 24(4S) Operation Manual 4 5.1 To set up ...