http://www.amphasys.com/sites/default/files/AmphaSoft-1.2.0_Release...
... arising when cancelling the closing of the Worklist window o Changing of the last Demodulation field ... arising when cancelling the closing of the Worklist window o Changing of the last Demodulation field ...
PowerPoint Presentation
... • Triggering x positive • Level 0.05 • Modulation 3 • Amplification 6 • Demodulation 2 • Chip D(120 um ... • Triggering x positive • Level 0.05 • Modulation 3 • Amplification 6 • Demodulation 2 • Chip D(120 um ...
http://www.amphasys.com/sites/default/files/AmphaSoft-1.2.3_Release...
... arising when cancelling the closing of the Worklist window o Changing of the last Demodulation field ... arising when cancelling the closing of the Worklist window o Changing of the last Demodulation field ...
http://www.amphasys.com/sites/default/files/AmphaSoft-1.2.4_Release...
... last Demodulation field caused the pump value to change - Version 1.1.1 Description: New Chip ... last Demodulation field caused the pump value to change - Version 1.1.1 Description: New Chip ...
http://www.amphasys.com/sites/default/files/AmphaSoft-1.2.6_Release...
... closing of the Worklist window o Changing of the last Demodulation field caused the pump value to change ... closing of the Worklist window o Changing of the last Demodulation field caused the pump value to change ...
http://www.amphasys.com/sites/default/files/AmphaSoft-1.2.8_Release...
... last Demodulation field caused the pump value to change - Version 1.1.1 Description: New Chip ... last Demodulation field caused the pump value to change - Version 1.1.1 Description: New Chip ...
Amphasys - Pollen Viability for Kiwi based on Impedance Flow Cytometry
... • Triggering x positive • Level 0.1 – 0.2 • Modulation 3 • Amplification 6 • Demodulation 1 • Pump speed 350 ... • Triggering x positive • Level 0.1 – 0.2 • Modulation 3 • Amplification 6 • Demodulation 1 • Pump speed 350 ...
Amphasys - Pollen Viability for Kiwi based on Impedance Flow Cytometry
... • Demodulation 0 • Flush on • Pump speed 60 rpm Analysis • Impedance at 2 MHz is suitable for viability and 12 ... • Demodulation 0 • Flush on • Pump speed 60 rpm Analysis • Impedance at 2 MHz is suitable for viability and 12 ...
Amphasys - Pollen Viability for Wheat based on Impedance Flow Cytometry
... • Demodulation 0 • Flush on • Pump speed 60 rpm Analysis • Impedance at 2 MHz is suitable for viability and 12 ... • Demodulation 0 • Flush on • Pump speed 60 rpm Analysis • Impedance at 2 MHz is suitable for viability and 12 ...
Amphasys - Ampha Z32 User Guide
http://www.amphasys.com/sites/default/files/Ampha_Z32_User_Guide_2.0.3.pdf, Amphasys - Ampha Z32 User Guide Amphasys, Technopark Lucerne, CH-6039 Root D4, Switzerland | Phone +41 41 541 91 20 | ww...